Ceilings

Back To Top Back To Top

Halcyon™ Healthcare Acoustical Ceiling - HC629HC

Fiber Glass light weight acoustic false ceiling panels with monolithic visual offer exceptional noise reduction and excellent light reflection to reduce light fixtures and are a low-VOC emitting panel solution.
Features
  • Water repellent membrane designed to be durable and safe with common disinfectants
  • Fiber Glass substrate with monolithic visual reducing installation time
  • Exceptional Sound Absorption with NRC values up to 1
  • High Light Reflectance (LR-0.88) reduces light fixtures & Energy use
  • Recommended to be used with AX grid for hospitals high-humidity or wet-cleaned areas
  • Washable & Scrubbable finish
  • Impact & Scratch Resistant
  • Available in Plank Sizes compatible with Logix Integrated Ceiling System
Specifications
Physical Properties
  • Materials Classification: Type: XII, Form: 2, Pattern: E, G
  • Substrate and Surface Finish: Fiberglass substrate finished with painted fiberglass scrim
  • Thickness: 19mm, 25mm, 38mm
  • Size: 600 x 600mm, 610 x 610mm, 600 x 1200mm, 610 x 1220mm
  • Edge Detail Trim: Square, Reveal [SL, FL]
  • Weight: 19mm [2.1 kg/m²], 25mm [2.4 kg/m²], 38mm [3.6 kg/m²]
  • Noise Reduction Coefficient [NRC]: [0.95] [1.0]
  • Ceiling Attenuation Class [CAC]: [24 dB] [25 dB] [28 dB] [31 dB]
  • Mold Prevention Application as per ASTM D3273: Fiberglass substrate is inherently resistant to the growth of mold and mildew
  • Humidity Resistance: Maximum 99% RH / 40°C for ClimaPlus
  • Light Reflectance Coefficient [LR]: 0.88
  • Color: Standard White similar to RAL 9016. Other colors are available upon request
  • Surface Burning Characteristics as per ASTM E84: Class A, Flame Spread:25, Smoke development:15
  • Thermal Resistance: 19mm [0.6 m² °K/W - R 3.5], 25mm [0.74 m² °K/W - R 4.2], 38mm [1.12 m² °K/W- R 6.6]
  • Washability / Scrubbability as per ASTM D4828 & D2486: Exceeds 1000 Wash/Scrub cycles without surface break or the extent of abrasion upon request
  • Relevant LEED Credit: EA Credit 1 | MR Credit 4| MR Credit 5 | MR Credit 6 IEQ Credit 3 | IEQ Credit 3.2 | IEQ Credit 4.6 | IEQ Credit 8.1 | IEQ Credit 9
Applications as per 2018 FGI guidelines
  • Class 1 MRI & Imaging Rooms
  • Food Preparation
  • Food Storage
  • Laboratories
  • Laundry Areas
  • Lobbies
  • ICU / NICU
  • Pharmacies
  • Waiting Areas
  • Ware Washing

Item

HC669HC
HC669HC
HC669HC
HC669HC
HC669HC
HC229HC
HC629HC
HC249HC
HC6625HC
HC2225HC
HC6225HC
HC2425HC
HC6638HC
HC2238HC
HC6238HC
HC2238HC
HCRF6625HC
HCRF2225HC
HCRF6225HC
HCRF2425HC
HCR6625HC
HCR2225HC
HCR6225HC
HCR2425HC